• Parker Lucifer 121K6423 & 122K8321 2/2 Way Fuel Solenoid Valve | Normally Closed / Normally Open for Burner Boiler Marine
  • Parker Lucifer 121K6423 & 122K8321 2/2 Way Fuel Solenoid Valve | Normally Closed / Normally Open for Burner Boiler Marine
  • Parker Lucifer 121K6423 & 122K8321 2/2 Way Fuel Solenoid Valve | Normally Closed / Normally Open for Burner Boiler Marine
  • Parker Lucifer 121K6423 & 122K8321 2/2 Way Fuel Solenoid Valve | Normally Closed / Normally Open for Burner Boiler Marine
  • Parker Lucifer 121K6423 & 122K8321 2/2 Way Fuel Solenoid Valve | Normally Closed / Normally Open for Burner Boiler Marine
  • Parker Lucifer 121K6423 & 122K8321 2/2 Way Fuel Solenoid Valve | Normally Closed / Normally Open for Burner Boiler Marine
  • Parker Lucifer 121K6423 & 122K8321 2/2 Way Fuel Solenoid Valve | Normally Closed / Normally Open for Burner Boiler Marine
  • Parker Lucifer 121K6423 & 122K8321 2/2 Way Fuel Solenoid Valve | Normally Closed / Normally Open for Burner Boiler Marine

Parker Lucifer 121K6423 & 122K8321 2/2 Way Fuel Solenoid Valve | Normally Closed / Normally Open for Burner Boiler Marine

No.121K6423,122K8321
Parker Lucifer K series Cat.No 121K6423 (Normally Closed) & Cat.No 122K8321 (Normally Open) direct acting 2/2-way G1/4 solenoid valves. Brass body with ruby seal, 0–30 bar working pressure, zero differential pressure start, millisecond fast response, TÜV certified. 121K6423 closes when power off for fuel safety shut-off; 122K8321 keeps flow when power off for bypass interlock control. Widely used for fuel lines of oil burners, industrial boilers and marine engine rooms.
  • Parker Lucifer 121K6423 & 122K8321 2/2 Way Fuel Solenoid Valve | Normally Closed / Normally Open for Burner Boiler Marine
  • Parker Lucifer 121K6423 & 122K8321 2/2 Way Fuel Solenoid Valve | Normally Closed / Normally Open for Burner Boiler Marine
  • Parker Lucifer 121K6423 & 122K8321 2/2 Way Fuel Solenoid Valve | Normally Closed / Normally Open for Burner Boiler Marine
  • Parker Lucifer 121K6423 & 122K8321 2/2 Way Fuel Solenoid Valve | Normally Closed / Normally Open for Burner Boiler Marine

Description

Product Specifications

Specification

121K6423(NC)

122K8321(NO)

Brand

Parker Lucifer

✅

✅

Valve Type

2/2 Way, Direct Acting

✅

✅

Function

Normally Closed / Normally Open

Power off to shut down, power on to start up

Power off to conduct, power on to disconnect

Port

G1/4" BSPP Female

✅

✅

Orifice

Orifice

3.0 mm

2.5 mm

Kv Value

Flow Coefficient

4.5 L/min

3.5 L/min

Pressure

Working Pressure

0–30 bar

0–30 bar

Media Temp

Media Temperature

-30℃ ~ +160℃

-30℃ ~ +160℃

Ambient Temp

Ambient Temperature

0℃ ~ 60℃

0℃ ~ 60℃

Body

Brass CW617N

✅

✅

Seal

Ruby Seat

✅

✅

Coil

483824, 19W

✅

✅

Insulation Class

Class H (180℃)

✅

✅

Protection

IP67 / IP44 Optional

✅

✅

Duty Cycle

100% Continuous Duty

✅

✅

Media

Fuel oil, light oil, heavy oil, lube oil, neutral gas

✅

✅

Certification

TÜV DIN CERTCO, EN264/EN267/TRD411

✅

✅


Product Advantages

1. Two models available in one series: 121K6423 NC and 122K8321 NO, to match different safety circuit logic

2. Direct acting design, operates at 0 bar differential pressure, stable performance for low-pressure oil lines

3. Ruby hard seal, high temperature and fuel corrosion resistance, longer service life than normal rubber seals

4. Built-in filter inside valve, block particles to avoid sticking and internal leakage

5. 360° rotatable coil housing, suitable for compact installation in engine room and boiler cabinet

6. Shared coil 483824, 19W, unified spare parts for easy stock management

7. TÜV burner safety certification, direct replacement for Riello, Weishaupt and other imported burner valves

8. Modular construction, seal service kit replaceable separately to save maintenance cost


Working Principle

Both are direct-acting 2/2-way solenoid valves. The coil generates magnetic force to drive the armature when energized, and spring resets after power off.
✅ Cat.No 121K6423 NC: Spring closes the valve when de-energized; magnetic force lifts the armature to open flow when energized. Mainly for safety shut-off, auto fuel cut once power loss.
✅ Cat.No 122K8321 NO: Spring keeps valve open for flow when de-energized; magnetic force closes valve to cut flow when energized. Suitable for bypass and energized-shutdown interlock circuits.
Direct acting without pilot structure, no required differential pressure, stable operation under low pressure.

Application Scenarios

  • Fuel line on-off and safety protection for oil burners and atomizing burners

  • Fuel pipeline control for industrial steam boilers and heating systems

  • Automatic fuel & lube oil control in marine engine room

  • Neutral gas and compressed air circuit control

  • Fluid interlock for thermal and petroleum equipment

  • Replacement spare parts for imported burners (Riello, Weishaupt, Oilon etc.)


Maintenance Instructions

1. Flush pipeline thoroughly before installation, install upstream strainer to protect ruby sealing surface
2. Regularly check coil temperature, terminals and cable gland to prevent moisture ingress
3. Inspect carbon and coke deposits on seat before restart after long idle period, clean if necessary
4. Clean with fuel-compatible solvent; do not scratch ruby disc with hard tools
5. Never remove coil while energized; avoid rapid cycling to prevent coil overheating
6. Check O-ring aging regularly, replace seal service kit as needed


Spare Parts & Accessories
Universal coil 483824 (19W, voltage suffix P8/T1/2P/Q9), seal service kit (ruby disc, O-rings, spring, armature assembly), coil housing, DIN43650 connector, cable gland, upstream strainer

Acceptance Standard

1. Verify model (121K6423 /122K8321), coil voltage and power match purchase order

2. Visual check: brass body free of porosity and cracks, intact threads and protective plugs

3. Function test: NC/NO logic matches model, smooth action without sticking or abnormal noise

4. Pressure holding test: no external leakage, no internal leakage at sealed status

5. Coil insulation resistance qualified, good protection sealing

6. Original packing, certificate and TÜV documents available for verification

Key Highlights
Classic Parker Lucifer K series, 121K6423 NC & 122K8321 NO sold together, one-stop solution for two kinds of burner safety circuit logic. Durable ruby hard seal, zero differential start, fast response. Interchangeable coil for easy stock. TÜV certified, popular replacement parts for marine, boiler maintenance and burner supply trade.

FAQ

Q1:What is the main difference between 121K6423 and 122K8321?

A1:121K6423 is NC (close on power loss), ideal for safety shut-off. 122K8321 is NO (open on power loss), for energized-shutdown interlock. They share same coil but different orifice and Kv flow rate.

Q2:Does it need pressure differential to open?

A2:No, direct acting design works at 0 bar differential pressure, suitable for low-pressure oil lines.

Q3:What coil voltage options are available?

A3:Common T1=230V, P8=115V. Confirm voltage suffix before order.

Q4:Can the coil be interchanged between two models?

A4:Yes, same coil part No.483824, 19W, just match voltage.