Flame monitor for Burners in Marine Boilers

No.LAE10
Flame amplifier is a kind of flame detector with high sensitivity and fast reaction speed. It is based on the photoelectric principle, through the probe to sense the surrounding light changes, and then determine whether there is a fire.It mainly involves the process of flame signal collection, conversion and amplification.
  • Flame monitor for Burners in Marine Boilers
  • Flame monitor for Burners in Marine Boilers
  • Flame monitor for Burners in Marine Boilers
  • Flame monitor for Burners in Marine Boilers
  • Flame monitor for Burners in Marine Boilers

Description

Targeted Flame Detection for Marine Boiler Systems
This flame monitor is engineered specifically for marine boiler burner systems, designed to provide real-time, high-accuracy flame detection critical to combustion control. Intended primarily for marine engineering professionals and ship operators, it integrates seamlessly within existing monitoring frameworks catered by marine boiler parts manufacturers. The device enhances operational safety by detecting flame presence and anomalies, supporting preventive maintenance while complying with marine safety standards. Our marine boiler spare parts supply ensures consistent availability for vessel operators requiring dependable flame monitoring components.

Advanced Technical Specifications and Functional Features
Utilizing the photoelectric principle, the flame monitor captures infrared radiation emitted by burner flames and converts this into an electrical signal, which is then amplified and analyzed. With dual-channel detection and self-safety functions, the unit provides robust, fail-safe performance in marine environments. Key measurable specifications include compatibility with standard 220~240V power supplies at 50~60Hz, a 0-20mA output signal for system integration, and LED flame status indicators. It weighs 305g and features dimensions optimized for marine boiler parts factory standards, enabling efficient installation and maintenance.

Industrial Relevance and Operational Integration on Ships
Within marine boiler operations, this flame monitor plays a vital role in combustion safety and efficiency optimization across commercial vessels globally. It facilitates early flame failure detection and continuous monitoring of radiation intensity and flicker frequency, which are essential parameters for burner adjustment and system diagnostics. Integration with burner control systems is streamlined due to standardized output and compatibility, supporting regulatory compliance and improving operational ROI for ship managers. The product is part of a comprehensive marine boiler spare parts wholesale portfolio addressing critical safety and monitoring needs.

Specification

Product Name Flame amplifier
Brand SIEMENS
Model LAE10
Power 5VA
Voltage 220~240V
Frequency 50~60Hz
Weight 305g
Size 8.5*6*9cm





Working Principle
The working principle of a flame amplifier can be divided into three steps:
1、Signal collection and conversion:
Flame detectors usually generate infrared radiation from the primary burning area of the burner flame, which is transmitted to the probe part of the detector through the optical fiber. In the probe, the infrared radiation is converted into an electrical signal by a photoresistor. ‌
2、Signal amplification and processing:
The electrical signal is then sent to the amplifier for amplification processing. This signal is compared with an adjustable reference voltage after passing through a frequency response switch and an amplifier. If the flame signal is greater than the reference signal, the trigger is set to "1" and outputs a signal to the flame detection line, thus indicating the presence of a flame.
3、Real-time monitoring:
The fire detector amplifier can display the flicker frequency of the flame, radiation intensity and other parameters in real time, and these data are very useful for monitoring the combustion of the flame inside the boiler. ‌

In general, the flame amplifier captures the infrared radiation generated by the flame, converts it into an electrical signal, amplifies and processes it, and finally realizes the monitoring of the presence and status of the flame.

Classification
According to the different characteristics and application scenarios of flame amplifiers, they can be classified into the following types:
1. Infrared flame detection amplifier:
The use of optical devices and electronic amplifiers to detect infrared radiation, so as to detect the presence of flame.
2. Ultraviolet flame detection amplifier:
The use of ultraviolet optical devices to detect the ultraviolet radiation generated by the combustion of natural gases or specific substances.
3. Pyroelectric flame detection amplifier:
The electric signal generated by pyroelectric materials is used to detect the heat generated by the combustion reaction.

Application
Flame amplifiers are widely used in industry, building safety, aviation, national defense and other fields. Among them, the industrial field is the most common application scenario, mainly used for fire warning and alarm in petrochemical, chemical, electric power, steel and other fields. In building safety, flame detection amplifiers can be used for fire detection in high-rise buildings, shopping malls, hotels and other places.

Characteristic
The main features of the flame amplifier include self-safety detection, ‌ dual-channel detection channel, ‌ standard power supply, ‌ digital flame frequency rating, ‌LED flame status indicator, ‌, and one 0-20mA measurement output. ‌


FAQ

What components are used in the flame monitor for marine boilers?
The flame monitor is manufactured under the JIEXI brand using SIEMENS components, ensuring high reliability and compliance with marine standards. This combination supports the supply of consistent, durable marine boiler spare parts suitable for demanding shipboard environments.

Can the flame monitor be customized to fit specific marine boiler models?
JIEXI offers flame monitors designed for integration with standard marine boiler burners. While the product supports typical burner flame systems, customization options depend on specific marine boiler requirements. Contact our experts for compatibility and tailored solutions in marine boiler parts supply.

What installation considerations are there for the flame monitor?
Installation requires compatibility with 220~240V, 50~60Hz power supply, typical in marine vessels. The monitor’s LED indicators and dual-channel detection simplify identification of flame status. Proper connection to the marine boiler control system ensures optimal integration with existing burner management.

How does JIEXI handle shipping and delivery for marine boiler parts?
JIEXI maintains a robust logistics network for global distribution of marine boiler parts wholesale and spare parts. We ensure timely delivery backed by professional packing and handling, minimizing downtime for marine operations. Contact us to discuss shipping options tailored to your location and order size.

Download

Leave a message
FirstName*
LastName*
Email*
Message*
Whatsapp/Phone
Verification Code*
Verification Code